temperature test & conditioning applications

ThermoStream Configurations

Temptronic's ATS Mobile Temperature Systems deliver temperatures from -100 to +300°C. All systems provide remote communications via IEEE 488 and RS-232, and two temperature outputs for control measured at the thermal head or directly at the DUT.

A variety of configurations allow flexibility to optimize your floor space and access to the DUT. Models ending in "-M" have an articulated arm and head that can be raised and lowered over test setups. Model ending in "-T" have a turret and hose for connecting to enclosures, MobilTempTM chambers, or custom test setups.

For details click on any of the links below or visit the Resource Center.
Accessories to view accessories such as enclosures with dry-air purge and anti-ESD mats.

 bench top temperature forcing systembench top temperature forcing systemTemperature Forcing - self contained airentry level, high performance temperature system

500 & 600 Series Mobile Temperature Environments

ModelATS-505,  605ATS-515,  615ATS-525,  625ATS-535,  635ATS-545,  645
LN2 or LCO2 not required
Temperature Range (at thermal head) -20 to +225°C -45 to +225°C -60 to +225°C   -80 to +225°C
System Airflow Output 4 to 10 scfm
(1.9 to 4.7 l/s)
4 to 10 scfm
(1.9 to 4.7 l/s)
5 scfm (2.4 l/s) Fixed Flow 5 scfm (2.4 l/s) Fixed Flow 4 to 18 scfm (1.8 to 8.5 l/s) Continuous





















Transition Rates 0 to +125°C, <3 min
+125 to 0°C, <4 min
-40 to +125°C, <12 sec
+125 to -40°C, <40 sec
-40 to +125°C, <12 sec
+125 to -40°C, <40 sec
-40 to +125°C, <12 sec
+125 to -40°C, <40 sec
-55 to +125°C, <10 sec
+125 to -55°C, <10 sec
Temperature Display & Resolution ±1°C ±1°C ±1°C ±1°C ±1°C
Temperature Accuracy ±1°C ±1°C ±1°C ±1°C ±1°C
Directly Control Device Under Test (DUT)
DUT Control Sensors Type T or K Thermocouples Type T or K Thermocouples Type T or K Thermocouples Type T or K Thermocouples Type T or K Thermocouples
Remote interface IEEE.488, RS232 IEEE.488, RS232 IEEE.488, RS232 IEEE.488, RS232 IEEE.488, RS232
Thermal Cap with protection from condensation at DUT site
Compact, portable system Fits bench top Easily integrates to bench top Easily integrates to bench top LabView™ drivers LabView™ drivers
CE Compliant and CFC-free
Facility requirements CDA at 90 psi minimum; Various power requirements available 130-240 VAC, 50/60Hz Built-in compressor;
No facility air needed
Same as ATS-505 to 625

 

 Temperature Forcing Systems for electronics testingTemperature Forcing Systems for electronics testingTemperature Forcing Systems for electronics testingTemperature Forcing Systems for electronics testing

700 & 800 Series Mobile Temperature Environments

ModelATS-710,  810ATS-730,  830ATS-750,  850ATS-770,  870
LN2 or LCO2 not required
Temperature Range (at thermal head) -80 to +225°C -90 to +225°C -90 to +300°C -100 to +225°C
System Airflow Output 4 to 18 scfm (1.8 to 8.5 l/s) Continuous 4 to 18 scfm (1.8 to 8.5 l/s) Continuous 4 to 18 scfm (1.8 to 8.5 l/s) Continuous 4 to 12 scfm (1.8 to 5.6 l/s) Continuous
Transition Rates -55 to +125°C, <10 sec
+125 to -55°C, <10 sec
-55 to +125°C, <10 sec
+125 to -55°C, <10 sec
-40 to +125°C, <12 sec
+125 to -40°C, <40 sec
-55 to +125°C, <10 sec
+125 to -55°C, <10 sec
Temperature Display & Resolution ±1°C ±1°C ±1°C ±1°C
Temperature Accuracy ±1°C ±1°C ±1°C ±1°C
Directly Control Device Under Test (DUT)
DUT Control Sensors Type T or K Thermocouples,
RTD (100 Ohm)
Type T or K Thermocouples Type T or K Thermocouples Type T or K Thermocouples,
RTD (100 Ohm)
Remote interface IEEE.488, RS232 IEEE.488, RS232 IEEE.488, RS232 IEEE.488, RS232
Thermal Cap with protection from condensation at DUT site
LabView™ drivers
CE Compliant and CFC-free
Heated Defrost -
Reduced Power Mode - heat only when using cold temperatures -
Automatic Power Reduction - reduce power usage during idle time -
Mechanical Arm or Turret Configuration
Optional Extended Height & Reach configuration for Mechanical Arm
Thermal Cap size options & Flexhose to connect external thermal chamber or test enclosure
Facility requirements CDA at 90 psi minimum; Various power requirements available 130-240 VAC, 50/60Hz