ThermoStream-Thermal Test Systems

Temptronic - 100px tall

ThermoStream® Thermal Test Systems

Need a Quote?
Application Questions?
Thermometer

Broad Temperature Ranges
-100 to +300°C

Options

Rapid, Accurate Transitions
Up to 40°C/min., ± 1.0°C

Multiple Sizes - 2

Benchtop and Floor Standing Models

ATS710E Screen

E Series Systems Equipped with Embedded Software Controls, Eliminating Windows® OS

· Significant reduction in security vulnerabilities
· Minimizes software and hardware obsolescence concerns
· Improved responsiveness of the touch screen
· Faster system boot and startup times

Mobile Temperature Environments

Temptronic ThermoStreams are portable systems that deliver clean dry air for precision temperature testing or conditioning of electronics (ICs, MEMS, transceivers, or circuits) and materials. No other systems can bring your test subjects to temperature faster with precise control.

With rapid thermal cycling or long saturation at a precise temperature, these systems optimize throughput for characterization, verification, thermal shock or failure analysis applications – at the test bench or on the production floor.

• No LN2 or LCO2 required

• -100 to +300°C

• Programmable transitions, up to 15°C/sec

• 1.0°C accuracy

• Extended reach for easy DUT access

• Integrated purging system prevents moisture buildup on the DUT

• NEW! Quick-connect feature for thermal caps

Here's More Information

Datasheets for N. American Installations (60Hz only)

ATS-605 THERMOSTREAM® DATASHEET AND SPECIFICATIONS

ATS-605 ThermoStream

Bench-top temperature system, ideal for temperature test and conditioning in design and laboratory environments. Capable of low temperature cooling without the need for LN2 or LCO2.

Power Requirements

115 ±10% VAC, 60 Hz only, 15 amp, 1phase

230 ±10% VAC, 60 Hz only, 10 amp, 1phase

Temperature Range
-20 to +225°C

Transition Rates
Heating: 0 to +125°C, <3 min
Cooling: +125 to 0°C, <4 min

Get the data sheet: ATS-605 THERMOSTREAM® DATASHEET AND SPECIFICATIONS


ATS-615 THERMOSTREAM® DATASHEET AND SPECIFICATIONS

ATS-615 ThermoStream

Mobile temperature system, ideal for thermal testing or conditioning in design and laboratory environments. Capable of low temperature cooling without the need for LN2 or LCO2.

Power Requirements

115 ±10% VAC, 60Hz only, 20amp (15amp available)

220 ±10% VAC, 60Hz only, 20amp

Temperature Range
-45 to +225°C

Transition Rates
Heating: -40 to +125°C, <12 sec
Cooling: +125 to -40°C, <40 sec

Get the data sheet: ATS-615 THERMOSTREAM® DATASHEET AND SPECIFICATIONS


ATS-625 THERMOSTREAM® DATASHEET AND SPECIFICATIONS

ATS-625 ThermoStream

Compact, high-speed temperature test system for testing and characterization of materials and electronics including ICs, MEMS and circuits. MIL-STD and commercial testing at ultra-low temperatures without the need for LN2 or LCO2.

Power Requirements

115 ±10% VAC, 60Hz only, 20amp

220 ±10% VAC, 60Hz only, 20amp

Temperature Range
-60 to +225°C

Transition Rates
Heating: -40 to +125°C, <12 sec
Cooling: +125 to -40°C, <40 sec

Get the data sheet: ATS-625 THERMOSTREAM® DATASHEET AND SPECIFICATIONS


ATS-635 THERMOSTREAM® DATASHEET AND SPECIFICATIONS

ATS-635 ThermoStream

Compact, high-speed temperature test system for testing and characterization of materials and electronics including ICs, MEMS and circuits. MIL-STD and commercial testing at ultra-low temperatures without the need for LN2 , LCO2 , or compressed air.

Power Requirements

Chiller Power: 220 ±10% VAC, 60Hz only, 16amp

Compressor Power: 220 ±10% VAC, 60Hz only, 30amp

Temperature Range
 -60 to +225°C

Transition Rates
Heating: -40 to +125°C, <12 sec
Cooling: +125 to -40°C, <40 sec

Get the data sheet: ATS-635 THERMOSTREAM® DATASHEET AND SPECIFICATIONS


ATS-645 THERMOSTREAM® DATASHEET AND SPECIFICATIONS

ATS-645 ThermoStream

Mobile temperature environments for high-speed testing, characterization and thermal shock of materials and electronics including ICs, MEMS, optical transceivers, and circuits. MIL-STD and commercial testing at low temperatures without the need for LN2 or LCO2.

Power Requirements

200 - 250 VAC (230V nominal) 60Hz only, 30 amp, 1phase

Temperature Range
-80 to +225°C

Transition Rates
Heating: -55 to +125°C, <10 sec
Cooling: +125 to -55°C, <10 sec

Get the data sheet: ATS-645 THERMOSTREAM® DATASHEET AND SPECIFICATIONS


ATS-810E-M THERMOSTREAM® DATASHEET AND SPECIFICATIONS

ATS-810-M ThermoStream

Mobile thermal environments for high-speed temperature testing, characterization and thermal shock of materials and electronics including ICs, MEMS, optical transceivers, and circuits. MIL-STD and commercial testing at ultra-low temperatures without the need for LN2 or LCO2.

Power Requirements

200 - 250 VAC (230V nominal) 60Hz only, 30 amp, 1phase

Temperature Range
-80 to +225°C

Transition Rates
Heating: -55 to +125°C, <10 sec
Cooling: +125 to -55°C, <10 sec

Get the data sheet: ATS-810E-M THERMOSTREAM® DATASHEET AND SPECIFICATIONS


ATS-810E-T THERMOSTREAM® DATASHEET AND SPECIFICATIONS

ATS-810-T ThermoStream

Mobile thermal environments for high-speed temperature testing, characterization and thermal shock of materials and electronics including ICs, MEMS, optical transceivers, and circuits. MIL-STD and commercial testing at ultra-low temperatures without the need for LN2 or LCO2.

Power Requirements

200 - 250 VAC (230V nominal) 60Hz only, 30 amp, 1phase

Temperature Range
-80 to +225°C

Transition Rates
Heating: -55 to +125°C, <10 sec
Cooling: +125 to -55°C, <10 sec

Get the data sheet: ATS-810E-T THERMOSTREAM® DATASHEET AND SPECIFICATIONS


ATS-830E-M THERMOSTREAM® DATASHEET AND SPECIFICATIONS

ATS-830-M ThermoStream

Mobile thermal environments for high-speed temperature testing and characterization of materials and electronics including ICs, MEMS, optical transceivers, and circuits. MIL-STD and commercial testing at ultra-low temperatures without the need for LN2 or LCO2.

Power Requirements

200 - 250 VAC (230V nominal) 60Hz only, 30 amp, 1phase

Temperature Range
-90 to +225°C

Transition Rates
Heating: -55 to +125°C, <10 sec
Cooling: +125 to -55°C, <10 sec

Get the data sheet: ATS-830E-M THERMOSTREAM® DATASHEET AND SPECIFICATIONS


ATS-830E-T THERMOSTREAM® DATASHEET AND SPECIFICATIONS

ATS-830-T ThermoStream

Mobile thermal environments for high-speed temperature testing and characterization of materials and electronics including ICs, MEMS, optical transceivers, and circuits. MIL-STD and commercial testing at ultra-low temperatures without the need for LN2 or LCO2.

Power Requirements

200 - 250 VAC (230V nominal) 60Hz only, 30 amp, 1phase

Temperature Range
-90 to +225°C

Transition Rates
Heating: -55 to +125°C, <10 sec
Cooling: +125 to -55°C, <10 sec

Get the data sheet: ATS-830E-T THERMOSTREAM® DATASHEET AND SPECIFICATIONS


ATS-850E-M THERMOSTREAM® DATASHEET AND SPECIFICATIONS

ATS-850-M ThermoStream

High temperature mobile thermal environments for temperature testing and characterization of materials and electronics including ICs, MEMS, optical transceivers, and circuits. MIL-STD and commercial testing at ultra-low temperatures without the need for LN2 or LCO2.

Power Requirements

200 - 250 VAC (230V nominal) 60Hz only, 30 amp, 1phase

Temperature Range
-90 to +300°C

Transition Rates
Heating: -40 to +125°C, <12 sec
Cooling: +125 to -40°C, <40 sec

Get the data sheet: ATS-850E-M THERMOSTREAM® DATASHEET AND SPECIFICATIONS


ATS-870E-M THERMOSTREAM® DATASHEET AND SPECIFICATIONS

ATS-870-M ThermoStream

High temperature mobile thermal environments for temperature testing and characterization of materials and electronics including ICs, MEMS, optical transceivers, and circuits. MIL-STD and commercial testing at ultra-low temperatures without the need for LN2 or LCO2.

Power Requirements

200 - 250 VAC (230V nominal) 60Hz only, 30 amp, 1phase

Temperature Range
-100 to +225°C

Transition Rates
Heating: -40 to +125°C, <12 sec
Cooling: +125 to -40°C, <40 sec

Get the data sheet: ATS-870E-M THERMOSTREAM® DATASHEET AND SPECIFICATIONS


Datasheets for International Installations (50 or 60Hz)

ATS-505 THERMOSTREAM® DATASHEET AND SPECIFICATIONS

ATS-505 ThermoStream

Bench-top temperature system, ideal for temperature test and conditioning in design and laboratory environments. Capable of low temperature cooling without the need for LN2 or LCO2.

Power Requirements

200 - 250 VAC (230V nominal) 50/60Hz 10 amp, 1phase

Temperature Range
-20 to +225°C

Transition Rates
Heating: 0 to +125°C, <3 min
Cooling: +125 to 0°C, <4 min

Get the data sheet: ATS-505 THERMOSTREAM® DATASHEET AND SPECIFICATIONS


ATS-515 THERMOSTREAM® DATASHEET AND SPECIFICATIONS

ATS-515 ThermoStream

Mobile temperature test system for temperature test and conditioning in design and laboratory environments. Capable of low temperature cooling without the use of LN2 or LCO2.

Power Requirements

115 ±10% VAC, 60Hz, 20amp (15amp available)

100 ±10% VAC, 50Hz, 20amp (15amp available)

200 ±10% VAC, 50Hz, 16amp

220 ±10% VAC, 60Hz, 16amp

230 ±10% VAC, 50Hz, 16amp

Temperature Range
-45 to +225°C

Transition Rates
Heating: -40 to +125°C, <12 sec
Cooling: +125 to -40°C, <40 sec

Get the data sheet: ATS-515 THERMOSTREAM® DATASHEET AND SPECIFICATIONS


ATS-525 THERMOSTREAM® DATASHEET AND SPECIFICATIONS

ATS-525 ThermoStream

Under bench temperature test system for testing and characterization of materials and components including: ICs, MEMS and Optical Transceivers. MIL-STD and commercial testing at ultra-low temperatures without LN2 or LCO2.

Power Requirements

115 ±10% VAC, 60Hz, 20amp (15amp available)

100 ±10% VAC, 50Hz, 20amp (15amp available)

200 ±10% VAC, 50Hz, 16amp

220 ±10% VAC, 60Hz, 16amp

230 ±10% VAC, 50Hz, 16amp

Temperature Range
-60 to +225°C

Transition Rates
Heating: -40 to +125°C, <12 sec
Cooling: +125 to -40°C, <40 sec

Get the data sheet: ATS-525 THERMOSTREAM® DATASHEET AND SPECIFICATIONS


ATS-535 THERMOSTREAM® DATASHEET AND SPECIFICATIONS

ATS-535 ThermoStream

Mobile temperature system for thermal testing or conditioning in design and laboratory or environments. Achieves wide temperature range without the need for LN2 , LCO2 , or compressed air. Ideal for design centers located in areas without a facilities air supply.

Power Requirements

Chiller Power: 220 ±10% VAC, 50/60Hz, 16amp

Compressor Power: 220 ±10% VAC, 50/60Hz, 30amp

Temperature Range
 -60 to +225°C

Transition Rates
Heating: -40 to +125°C, <12 sec
Cooling: +125 to -40°C, <40 sec

Get the data sheet: ATS-535 THERMOSTREAM® DATASHEET AND SPECIFICATIONS


ATS-545 THERMOSTREAM® DATASHEET AND SPECIFICATIONS

ATS-545 ThermoStream

Mobile thermal test systems for high-speed temperature testing and characterization of materials and components including: IC's, MEMS, and Optical Transceivers. MIL-STD and commercial testing at ultra-low temperatures without LN2 or LCO2.

Power Requirements

200 - 250 VAC (230V nominal) 50/60Hz 30 amp, 1phase

Temperature Range
-80 to +225°C

Transition Rates
Heating: -55 to +125°C, <10 sec
Cooling: +125 to -55°C, <10 sec

Get the data sheet: ATS-545 THERMOSTREAM® DATASHEET AND SPECIFICATIONS


ATS-710E-M THERMOSTREAM® DATASHEET AND SPECIFICATIONS

ATS-710-M ThermoStream

Mobile thermal environments for high-speed temperature testing, characterization and thermal shock of materials and electronics including ICs, MEMS, optical transceivers, and circuits. MIL-STD and commercial testing at low temperatures without the need for LN2 or LCO2.

Power Requirements

200 - 250 VAC (230V nominal) 50/60Hz 30 amp, 1phase

Temperature Range
-80 to +225°C

Transition Rates
Heating: -55 to +125°C, <10 sec
Cooling: +125 to -55°C, <10 sec

Get the data sheet: ATS-710E-M THERMOSTREAM® DATASHEET AND SPECIFICATIONS


ATS-710E-T THERMOSTREAM® DATASHEET AND SPECIFICATIONS

ATS-710-T ThermoStream

Mobile thermal environments for high-speed temperature testing, characterization and thermal shock of materials and electronics including ICs, MEMS, optical transceivers, and circuits. MIL-STD and commercial testing at low temperatures without the need for LN2 or LCO2.

Power Requirements

200 - 250 VAC (230V nominal) 50/60Hz 30 amp, 1phase

Temperature Range
-80 to +225°C

Transition Rates
Heating: -55 to +125°C, <10 sec
Cooling: +125 to -55°C, <10 sec

Get the data sheet: ATS-710E-T THERMOSTREAM® DATASHEET AND SPECIFICATIONS


ATS-730E-M THERMOSTREAM® DATASHEET AND SPECIFICATIONS

ATS-730-M ThermoStream

Mobile thermal environments for high-speed temperature testing, characterization and thermal shock of materials and electronics including ICs, MEMS, optical transceivers, and circuits. MIL-STD and commercial testing at low temperatures without the need for LN2 or LCO2.

Power Requirements

200 - 250 VAC (230V nominal) 50/60Hz 30 amp, 1phase

Temperature Range
-90 to +225°C

Transition Rates
Heating: -55 to +125°C, <10 sec
Cooling: +125 to -55°C, <10 sec

Get the data sheet: ATS-730E-M THERMOSTREAM® DATASHEET AND SPECIFICATIONS


ATS-730E-T THERMOSTREAM® DATASHEET AND SPECIFICATIONS

ATS-730-T ThermoStream

Mobile thermal environments for high-speed temperature testing, characterization and thermal shock of materials and electronics including ICs, MEMS, optical transceivers, and circuits. MIL-STD and commercial testing at low temperatures without the need for LN2 or LCO2.

Power Requirements

200 - 250 VAC (230V nominal) 50/60Hz 30 amp, 1phase

Temperature Range
-90 to +225°C

Transition Rates
Heating: -55 to +125°C, <10 sec
Cooling: +125 to -55°C, <10 sec

Get the data sheet: ATS-730E-T THERMOSTREAM® DATASHEET AND SPECIFICATIONS


ATS-750E-M THERMOSTREAM® DATASHEET AND SPECIFICATIONS

ATS-750-M ThermoStream

Mobile, ultra-low to high temperature thermal environments for temperature testing, characterization and thermal shock of materials and electronics including: ICs, MEMS, and Optical transceivers. MIL-STD and commercial testing at ultra-low temperatures without LN2 or LCO2.

Power Requirements

200 - 250 VAC (230V nominal) 50/60Hz, 30 amp, 1 phase

Temperature Range
-90 to +300°C

Transition Rates
Heating: -40 to +125°C, <12 sec
Cooling: +125 to -40°C, <40 sec

Get the data sheet: ATS-750E-M THERMOSTREAM® DATASHEET AND SPECIFICATIONS


ATS-770E-M THERMOSTREAM® DATASHEET AND SPECIFICATIONS

ATS-770-M ThermoStream

Mobile, ultra-low to high temperature thermal environments for temperature testing, characterization and thermal shock of materials and electronics including: ICs, MEMS, and Optical transceivers. MIL-STD and commercial testing at ultra-low temperatures without LN2 or LCO2.

Power Requirements

200 - 250 VAC (230V nominal) 50/60Hz, 30 amp, 1 phase

Temperature Range
-100 to +225°C

Transition Rates
Heating: -40 to +125°C, <12 sec
Cooling: +125 to -40°C, <40 sec

Get the data sheet: ATS-770E-M THERMOSTREAM® DATASHEET AND SPECIFICATIONS


ThermoStream Accessories and Technical Papers

Hood Style ThermoChamber

Get our brochure: Hood Style ThermoChamber


Clamshell Style Thermo chamber

Get our brochure: Clamshell Style Thermo chamber


Front-Load Style Temperature Chamber

Get our brochure: Front-Load Style Temperature Chamber


T-Caps, Shrouds, and Mats for Temperature Forcing Enclosures

Get our brochure: T-Caps, Shrouds, and Mats for Temperature Forcing Enclosures


High Performance Air Dryer

Get our brochure: High Performance Air Dryer


Automated Thermal Testing of Power Devices

Get our brochure: Automated Thermal Testing of Power Devices


Temptronic mobile, high speed temperature environment

Get our brochure: Temptronic mobile, high speed temperature environment


Thermal Stress Testing: Breaking Old Habits

Get our brochure: Thermal Stress Testing: Breaking Old Habits


Four Ways to Contact Us for Support